VAD System |  | | General Information |  |
| Vendor |  | Thoratec | | Item |  | VAD System | | Features |  | Is the only system that offers circulatory support for either the left side of the heart, the right side of the heart, or both sides of the heart
As of June 2001, the Thoratec VAD System has been used in more than 1,700 patients
Has been used in over 170 medical centers worldwide
Has been used to support patients weighing from 17 kg to 144 kg and as young as 6 years old
Allows for perioperative device selection
Use of the Thoratec VAD has yielded increased patient survival rates when compared to control patients supported with conventional therapy only
Can inhibit organ deterioration while awaiting a donor heart
Is approved for reimbursement
Is FDA approved for bridge to cardiac transplantation and postcardiotomy recovery of the natural heart | | Dimensions |  | Inquire | | Weight |  | Inquire | | Regulatory Approval |  | FDA approved for bridge to cardiac transplantation and postcardiotomy recovery of the natural heart | | Coating |  | The VAD pumps are prosthetic ventricles consisting of a smooth, seamless pumping chamber enclosed in a rigid polysulfone case. The blood sac is manufactured from Thoralon®. Thoralon is composed of:
A base polymer, which provides enhanced strength, flexibility, and durability.
A Surface Modifying Additive (SMA)
Thoralon works exceptionally well because of its excellent:
Blood and tissue compatibility
Thromboresistance
Long-term fatigue characteristics
In vivo stability
| | Pump Design |  | pulsatile flow | | Output |  | Two mechanical tilting disc valves maintain unidirectional flow through the blood pump. A sensor detects when the VAD is full of blood and automatically signals the console to eject blood from the pump. In clinical practice, an effective stroke volume of 65 milliliters (ml) is possible with rates ranging from 20 to 110 beats per minute (bpm) and flow outputs ranging from 1.3 to 7.2 liters/minute (L/min). | | Pricing |  | Inquire |
 | | Product Description |  |
| The Thoratec VAD System includes three major components: Blood pump, Cannulae, and Dual Drive Console or TLC-II® Portable Driver. This system provides partial or total circulatory assistance when the natural heart, with conventional therapy, is unable to maintain adequate circulation to perfuse vital organs. To accomplish support, blood flows from the natural heart to the VAD, which then pumps pulsatile blood flow back to the body. |  |
| Thoratec | | Customer Service: (925) 847-8600 | | Web site: http://www.thoratec.com | | Please mention Medcompare.com when you contact the vendor. |
| NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary. |
|
|