> > > Portable ABI Kit

Portable ABI Kit

Portable ABI Kit
General Information
VendorHokanson
ItemPortable ABI Kit
Features
  • MD6 Doppler
  • MD6VR Chart Recorder
  • S300 Aneroid Sphygmomanometer
  • MD6 System Carrying Case
  • 2 SC10 Straight Segmental Cuffs
  • 2 SC12 Straight Segmental Cuffs
  • Training Materials SuppliedInquire
    Chart RecorderMD6VR
    Cuffs Supplied2 SC10 Straight Segmental Cuffs, 2 SC12 Straight Segmental Cuffs
    PricingInquire
    FinancingTo finance this purchase click here (U.S. customers only)
    Related Content
    Product Showcase  
    Product Description
    An Ankle Brachial Index (ABI) is one of the most simple to perform and useful vascular tests for assessing peripheral vascular disease. With the Portable ABI Kit, you get the basic equipment you'll need in order to perform a complete ABI. The ankle-arm pressure index (also known as the Ankle/Brachial Index or ABI) compares the systolic blood pressure of the ankle to that of the arm (brachial). These measurements are useful in the assessment, follow-up and treatment of patients with peripheral vascular disease (PVD). ABI's provide an objective baseline to follow the progression of the disease process and evaluate the effectiveness of the treatment plan.

    The ABI results are usually combined with Doppler or pulse volume waveform analysis. Significant changes in arterial systolic pressure between sites indicate reduced blood flow caused by obstruction of blood vessels. The effects of obstructions can be emphasized by increasing blood flow, either by exercise testing or by inducing reactive hyperemia with an occlusive cuff. Patients, such as diabetics, with calcified vessels may show falsely elevated ankle pressures. In this case, pressure measurements can be made on the foot or toes by Photo Plethysmography (PPG) for more accurate results. Diagnostic information is obtained both from the waveform of the arterial flow when displayed on a chart recorder and from using the PPG sensor to determine the blood pressure in the digit.

    To detect pressures a Doppler or PPG sensor is used. Pulse waveforms are recorded on a chart recorder.
    View Vendor Contact Information
    NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary.