> > > Webster Porterfield Deflectable Catheter

Webster Porterfield Deflectable Catheter

Webster Porterfield Deflectable Catheter
General Information
VendorBiosense Webster, a Johnson & Johnson Company
ItemWebster Porterfield Deflectable Catheter
Features
  • Multipurpose catheter specially designed for left sided mapping
  • Permits right ventricular pacing, and right ventricular and atrial recording using a single catheter; provides access to the RV outflow tract
  • Designed for subclavian or femoral insertion depending upon type of study preferred
  • LengthInquire
    Product NumberD7S-06R-POR-MS
    Tip size (French)7F
    Electrode Spacing4-13-4-65-4 mm
    CurveD
    Regulatory ApprovalUS FDA
    Electrode ConfigurationHexapolar
    PricingInquire
    Product Description
    The PORTERFIELD catheter incorporates six electrodes which are spaced to permit pacing and recording from a single catheter. Positioned in the Right Atrium, the catheter paces the atrium while recording atrial electrograms. The catheter may then be repositioned to the right ventricular apex for atrial recording and ventricular pacing and recording. If indicated, the catheter tip may be repositioned in the right ventricular outflow tract. If follow-up is anticipated, the PORTERFIELD catheter may be positioned from the subclavian and remain in place for subsequent drug assessment while the patient remains ambulatory. In many cases, no high right atrium (HRA) catheter is required because the PORTERFIELD catheter provides information about atrial and ventricular electrical activity. The catheter is placed via the subclavian or femoral vein to test defibrillator function or to define antiarrhythmic drug effect. The Biosense Webster Model D7S-06R-POR-MS is designed for use in small to medium size hearts, while the electrode spacing in the Model D7E-06R-POR-MS is intended to accommodate placement in hearts that are enlarged.
    View Vendor Contact Information
    NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary.