Rubicon Filter |  | | General Information |  |
| Vendor |  | Rubicon Medical Corp. | | Item |  | Rubicon Filter | | Features |  | - Filter is mounted on a standard 0.014'' guidewire
- Unique design and small crossing profile allows one-step insertion and deployment of both filter and stent
- Filter is deployed via a coaxial actuating wire at the proximal end of the guidewire
- Filter basket is supported by floating Nitinol™ struts for superior apposition in vessel
- 100 micron pore size is optimized for blood flow and capture efficiency
- Compatible with 6F guide catheters
- Large-bore catheter retrieval system is designed to minimize risk of debris loss during filter capture
- Unique retrieval system actuator with graphics shows physician the exact status of the filter as it is being captured
| | Approval |  | For investigational us only. Approval pending. | | Product Number |  | Inquire | | Shaft O.D. (inches) |  | Crossing profile: (nominal diameter of undeployed filter) 2.1, 2.4, 2.7F | | Total Length (cm) |  | 195 cm | | Pricing |  | Inquire |
 | | Related Content |  |
 | | Product Description |  |
| The Rubicon Filter System is an embolic protection device that safely traps and removes much of the debris that may be dislodged during interventional procedures. The Rubicon Filter System comprises several components. The first is a guidewire-mounted filter, and the second is a capture catheter. Other ancillary components supplied with the system for convenience of use include an introducer, a syringe for flushing the capture catheter, and two torque devices. The filter is mounted on a steerable 0.014" guidewire, which is designed to be compatible with devices delivered with a 0.014" guidewire. The coaxial actuating wire design eliminates the need for a delivery catheter, allowing a stent to be pre-loaded on the filter wire and delivered in a one-step insertion of both devices. The free-floating struts have three radiopaque markers and are designed to provide consistent apposition to tortuous vasculature. The distal tip is highly radiopaque and shapeable. When the procedure is completed, the capture catheter is telescoped over the filter and trapped debris, and then withdrawn. The capture catheter has a large bore sleeve designed to contain the collapsed filter and the debris trapped within it. The actuating device includes graphics that show the clinician the status of the filter throughout the retrieval process. |  |
 |
 |
| Rubicon Medical Corp. | | Customer Service: (801) 886-9000 | | Web site: | | Please mention Medcompare.com when you contact the vendor. |
| NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary. |
|
|