Medcompare - The Buyer's Guide for Medical Professionals General Surgery Buyer's Guide
Products New Products News Journal Updates Articles Resources Events
Search Medcompare
Enter Keyword(s):


Articles
Are All Scissors Created Equal? Not if You’re a Surgeon.
Are All Scissors Created Equal? Not if You’re a Surgeon.
Advertisement
> > > Lyra-i™ Laser System

Lyra-i™ Laser System

Lyra-i™ Laser System
General Information
VendorIRIDEX
ItemLyra-i™ Laser System
Features
  • 1mm to 5 mm variable and 10-mm spot size for the safe and effective treatment of facial wrinkles, leg veins, hair removal and shaving bumps.
  • The Lyra-i's Unique wavelength and flat beam profile maintain laser energy in the therapeutic range avoiding dangerous peak powers.
  • Continuous parallel contact cooling combined with 1064 nm epidermal transparency protect the epidermis, permitting the safe treatment of all-skin types, and patients with recent sun exposure.
ApprovalWorldwide
Product NumberInquire
Dimensions23" (L) x 12" (W) x 17" (H)
Weight73 lbs
Wavelength1064 nm
LaserNd:YAG
ApplicationCollagen Stimulation
Vascular Lesions
Hair Removal
Cooling SystemInternal, water-to-air cooled
Pulse Duration20 to 100 ms
Pulse WidthInquire
Repetition RateInquire
Electrical Requirements208 VAC/20 Amps, 60 Hz
PricingRequest Quote     
Related Content
Quick Pick  
Product Description
The Lyra-i system combines the longest available wavelength with a unique flat beam profile to maximize patient safety and efficacy. The unique flat beam profile consistently delivers energy in the therapeutic range to all targeted structures. The Lyra-I uniquely avoids high peak powers ensuring patient safety. All Lyra-I patients are protected by patented continuous parallel contact cooling that protects the epidermis. These unique features provide optimal results through deep penetration to the hair bulb, deeper leg vein and to the papillary dermis for dermal remodeling while maximizing patient safety The remarkable depth of penetration of 1064nm is due to its low scattering and epidermal transparency allowing the effective delivery of energy to deeply seated targets, such as blue and purple vessels while safely avoiding epidermal pigment. Computer adjusted fluence, delivered in adjustable pulse widths coupled with 1mm to 5mm continuously adjustable spot size is ideal for treating vessels from .5 mm to 4 mm.
Go to Vendor Product Page
Go to Vendor Website
View Vendor Contact Information
NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary.