SpectraMax M2 multi-detection microplate reader w/ dual-mode cuvette port |  | | General Information |  |
| Vendor |  | Molecular Devices Corporation | | Item |  | SpectraMax M2 multi-detection microplate reader w/ dual-mode cuvette port | | Features |  | Inquire | | Approval |  | Inquire | | Light source |  | Xenon flash lamp (1 joule/flash) | | Wavelength |  | 200-1000 nm | | Plates Accepted |  | 6, 12, 24, 48, 96, 384-wells | | Quantity |  | Inquire | | Exhaust |  | Inquire | | Dynamic Range |  | Inquire | | Pricing |  | Inquire | | Financing |  | To finance this purchase click here (U.S. customers only) |
 | | Product Description |  |
| SpectraMax M2 is a dual-monochromator, multi-detection microplate reader with a dual-mode cuvette port and 6-384 microplate reading capability. Detection modalities include absorbance (UV-Vis Abs) and fluorescence intensity (FI) and have optical performance comparable to a top-of-the-line dedicated spectrofluorometer or spectrophotometer. Endpoint, kinetic, spectrum and area-well scanning read types and PathCheck® allow homogeneous and heterogeneous microplate assays to be performed in this flexible system. The FI and Abs microplate reader with built-in cuvette port allows easy conversion and optimization of very-low-throughput assays into medium-high-throughput microplate assays. The SpectraMax M2 allows faster, more precise results and reagent savings. In addition, combined absorbance and fluorescence intensity assays can be run by issuing a single read command. dual monochromators There is no need for expensive filters. The system uses two scanning monochromators to determine optimal excitation and emission settings. Changing methods or fluorophores requires only a few mouse clicks to optimize the system. patented PathCheck Sensor The PathCheck Sensor is the only patented† technology available that measures the depth (optical pathlength) of samples in a microplate. With SoftMax® Pro software, it can automatically normalize the well absorbance to a cuvette equivalent pathlength of 1 cm — similar to using 96 or 384 cuvettes simultaneously. PathCheck allows you to eliminate standard curves. For compounds with a known extinction coefficient, concentration can be calculated directly from absorbance. |  |
 |
 |
| Molecular Devices Corporation | | Customer Service: (800) 635-5577 | | Web site: http://www.moleculardevices.com/ |  |
| NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary. |
|
|