> > > AXIS II PR Post Refractive Ultrasound

AXIS II PR Post Refractive Ultrasound

AXIS II PR Post Refractive Ultrasound
General Information
VendorQuantel Medical, Inc.
ItemAXIS II PR Post Refractive Ultrasound
Features
  • Precision A-Scan - Biometry clinically proven as accurate as partial coherence interferometry while not limited by dense media1
  • Scleral spike discrimination software eliminates optic nerve scans
  • Addresses the biometry challenge of "K” correction in post-refractive eyes with 6 post-refractive formulas
  • 6 Formulas for Normal eyes
  • .25 and .50 increment IOL Powers
ApprovalUS
Scan TypeA-scan ultrasound biometry
IOL FormulasSRK T, Holladay, Hoffer Q, Haigis, SRK II and Binkhorst II
PricingRequest Quote     
Related Content
Technology Spotlight  
Product Description
The number of patients requiring cataract surgery following refractive surgery grows larger each year. This has created a challenge for surgeons, as calculating IOL power for a modified cornea is difficult. True corneal power following RK, ALK, PRK and LASIK is difficult to accurately measure by keratometry or topography. For example, keratometry and simulated keratometry by topography will typically overestimate central corneal power in patients who have undergone keratorefractive surgery. With these concerns in mind, Quantel Medical has developed the new Axis II PR (post refractive) biometer. Based upon the patient’s historical data, doctors can choose from six post-refractive formulas. Additionally six standard IOL formulas are available. The six post-refractive formulas are: Double K/SRK-T, History Derived, Refraction Derived, Shammas, Rosa, and Contact Lens Method. The other six standard formulas are: SRK T, Holladay, Hoffer Q, Haigis, SRK II and Binkhorst II. IOL calculations can be displayed in .25D or .50D increments. With established clinical efficacy equivalent to the laser interferometer, the Axis II PR is intuitive and easy to use. A discrimination feature automatically eliminates optic nerve scans. An onsite inservice and a Prager Immersion Shell are always included.
Go to Vendor Product Page
Go to Vendor Website
View Vendor Contact Information
NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary.