Boomerang™ ClosureWire Vascular Closure System (VCS) |  | | General Information |  |
| Vendor |  | Cardiva Medical, Inc. | | Item |  | Boomerang™ ClosureWire Vascular Closure System (VCS) | | Features |  | - The Boomerang device provides immediate hemostasis and allows the arteriotomy to relax back around the Boomerang Wire while normal clotting mechanisms begin.
- The arteriotomy site closes via natural mechanisms—elastic recoil and thrombosis.
- The original arteriotomy (e.g., 8 Fr. OD for a 6 Fr. arterial sheath) is "down-sized" to diameter of Boomerang Wire (approximately a 20 gauge needle).
- The Boomerang device creates a site-specific compression of both the arteriotomy and tract, unlike manual compression where general pressure is diffused across a broad area.
- Temporary placement of low-profile, conformable disc against the intima provides immediate hemostasis and secure seal in the cath lab in under 30 seconds.
- Precise, targeted compression provides immediate hemostasis and allows the arteriotomy to close naturally and normal clotting mechanisms to begin.
| | Material |  | Nitinol braided mesh disc | | Approval |  | US | | Product Number |  | Inquire | | Sheath Size |  | NA | | Closure Site/Location |  | Femoral Arteriotomy | | Pricing |  | Inquire | | Financing |  | To finance this purchase click here (U.S. customers only) |
 | | Product Description |  |
| The Boomerang™ ClosureWire Vascular Closure System (VCS) utilizes a new technique called Arteriotomy Site-Specific Compression.
The Boomerang ClosureWire technique creates a site-specific compression between the inside of the arteriotomy and just outside the tissue tract, resulting in a targeted internal compression of both the arteriotomy and tract. The device is deployed, which creates immediate hemostasis and a secure seal in the cath lab in under 30 seconds. With the device in place, the arteriotomy relaxes back naturally around the Boomerang Wire (0.037 inches) while normal clotting mechanisms begin. Natural elastic recoil of the arteriotomy is known as the Boomerang Effect, which returns the arteriotomy to its original puncture size (approximately a 20 gauge needle). Following the procedure, the device is completely removed, leaving nothing in the artery or tissue tract. Final hemostasis is achieved with just a few minutes of occlusive finger pressure to close the remaining needle puncture site left by removing the Boomerang ClosureWire device. |  |
 |
 |
| Cardiva Medical, Inc. | | Customer Service: (650) 964-8900 | | Web site: http://www.cardivamedical.com | | Please mention Medcompare.com when you contact the vendor. |
| NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary. |
|
|