Erythropoietin RIA Test |  | | General Information |  |
| Vendor |  | Diagnostic Systems Laboratories, Inc. | | Item |  | Erythropoietin RIA Test | | Catalog Number |  | DSL-1100 | | Size |  | 100 tubes | | Range |  | 7, 5 - 200 mIU/mL | | Sample Type |  | Serum, Plasma | | Regulatory Status |  | For In Vitro Diagnostic Use | | Discipline |  | RIA | | Sensitivity |  | 1.7 mIU/mL | | Incubation Time |  | 4 hrs + 16-20 hrs + 30 mins at RT | | Pricing |  | Inquire |
 | | Product Description |  |
| Erythropoietin (EPO) is the primary known naturally-occurring stimulant of red blood cell production. The predicted molecular weight of human EPO is 18.2 kDa. Due to N-glycosylation, the circulating form of EPO has an estimated molecular mass of ~30.5 kDa. Although EPO itself appears to have a unique structure, the EPO receptor bears some homology to several other growth factor receptors, including those for interleukins 2 and 6, prolactin and growth hormone, suggesting possible functional similarities for these growth factor systems [1].
In the fetus, the liver is the major site of EPO production [1, 2, 3]. Postnatal production occurs primarily in the renal tubular epithelium, although significant continued postnatal hepatic production has been demonstrated [4]. EPO is secreted into the circulation from where it is taken up by target tissues. EPO binds to specific cell membrane receptors on erythroid progenitor cells and appears to facilitate erythrocyte differentiation, perhaps by increasing survival of the progenitor cells. Endogenous, N-glycosylated EPO is cleared at a constant rate, with a half-life estimated at 1.5 - 2 hours. The clearance rate is largely unaffected by EPO levels or tissue utilization. Therefore, circulating EPO levels reflect production rates [5].
- Jelkmann W Physiol Rev 72:449-489, 1992
- Tabbara IA Arch Intern Med 153:298-304, 1993
- Porter DL et al. Experiment Hematol 21:388-404, 1993
- Koury ST et al. Nephrol 13:78-86, 1993
- Spivak JL Annu Rev Med 44:243-253, 1993.
|  |
 |
 |
| Diagnostic Systems Laboratories, Inc. | | Customer Service: (800) 231-7970 | | Web site: http://www.dslabs.com | | Please mention Medcompare.com when you contact the vendor. |
| NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary. |
|
|