MM-PTH RIA Test |  | | General Information |  |
| Vendor |  | Diagnostic Systems Laboratories, Inc. | | Item |  | MM-PTH RIA Test | | Features |  | Inquire | | Approval |  | For In Vitro Diagnostic Use | | Product Number |  | DSL-2400 | | Size |  | 100 tubes | | Range |  | 6, 25 - 1000 pmol/L | | Sample Type |  | Serum, Plasma | | Sensitivity |  | 1.4 pmol/L | | Incubation Time |  | 3 hrs + 30 mins at 2-8C | | Storage / Stability |  | 8 wks | | Sample Size |  | 100 µL | | Pretreatment |  | None | | Format / Method |  | Double Antibody RIA | | Pricing |  | Inquire |
 | | Product Description |  |
| Parathyroid hormone (PTH) is synthesized by the parathyroid glands [1,2] and secreted in response to decreased extracellular calcium concentrations. PTH prevents hypocalcemia by enhancing bone resorption and decreasing calcium excretion by the kidney. Following release into the circulation, intact PTH is rapidly degraded into 4 fragments: N-terminal (residues 1-34), C-terminal (residues 35-84) and 2 mid molecule fragments (residues 44-68 and 35-64). The N-terminal fragment retains full biological potency, and is also rapidly degraded in the blood. The biologically inactive C-terminal and mid-molecule fragments are present in the circulation for a much longer period of time, resulting in C-terminal and Mid-Molecule concentrations which are approximately 5 to 10-fold higher than Intact or N-terminal PTH concentrations.
PTH acts directly on bone and kidney and indirectly on the intestine to alter calcium and phosphate concentrations in serum and urine. PTH is helpful in discriminating between primary hyperparathyroidism, where PTH levels are elevated, and nonparathyroid hypercalcemia [3,4]. Additionally, PTH is helpful for assessing parathyroid function in renal failure and is often used for dialysis patients.
- Endres DB, et al. Endocrinol Metab Clin North Am 18:611-629, 1989.
- Orloff JJ, et al. Endocrin Rev 10:476-195, 1989.
- Marcus R. Endocrinol Metab Clin North Am 18:647-658, 1989.
- Fitzpatrick LA & Bilezikian JP. Am J Med 82:275-282, 1987.
|  |
 |
 |
| Diagnostic Systems Laboratories, Inc. | | Customer Service: (800) 231-7970 | | Web site: http://www.dslabs.com | | Please mention Medcompare.com when you contact the vendor. |
| NOTE: Medcompare disclaims any information on this site. The information found on Medcompare (Drug Guide, Product Listings and otherwise) is intended for use by medical professionals. This information is not intended to replace the information, advice or instructions from a medical doctor. Pricing information is approximate, actual prices may vary. |
|
|